Air-to-wa­ter heat pump NIBE F2120

The NIBE F2120 is the air/water heat pump for maximum efficiency in new builds, modernization projects, or when replacing your existing heating system.

Application
Single-family house, multi-family house, new construction, renovation
Installation
Outdoor installation
Operating range
2.2 - 15.4 kW / Cascadable up to 8 units (max. 108 kW at A-7/W35)

Pro­duct de­tails

The ad­van­ta­ges of the NIBE F2120 at a glance:

  • Whisper-quiet operation
    Thanks to optimized technology
  • Minimum operating costs
    Through inverter technology to the optimum power range
  • Combination possibility
    up to 8 heat pumps in cascade
  • Milestone in efficiency
    With a SCOP greater than 5.0
  • Working range for any climate
    Flow temperature up to 65 °C
  • No vignette obligation
    Refrigerant not over 3 kg
  • Overview and status
    Through the Internet connection myuplink the full control and monitoring even remotely

Cli­ma­te pre­mi­um

Are you replacing a fossil gas or oil heating system with a renewable heating system? Benefit from attractive subsidies.

References

  • Einfamilienhaus | F2120 | Mehrfamilienhaus | Umgebungsluft

    Bayer, 8222 Beringen

  • Easytronic | F2120 | Mehrfamilienhaus | Stückholz | Umgebungsluft

    Burger, 5103 Möriken

  • Einfamilienhaus | F2120 | Umgebungsluft

    Faber, 8360 Eschlikon

Do you have any ques­ti­ons?

Benefit from our many years of experience and let our specialists advise you individually, without obligation and free of charge.

Fre­quent­ly as­ked ques­ti­ons?

The heat pump extracts thermal energy from the ambient air. The refrigerant absorbs this heat in the heat exchanger (evaporator) and is then compressed in the compressor. The heat generated in this process is used for heating and hot water production via another heat exchanger. In summer, the cycle can also be used for cooling by reversing the process.

The heat pump extracts thermal energy from the ground using a geothermal probe or groundwater. The refrigerant absorbs this heat in the heat exchanger (evaporator) and is then compressed in the compressor. The heat generated in this process is used for heating and hot water production via another heat exchanger. In summer, the cycle can also be used for cooling by reversing the process.

Heat pumps are suitable for both and can therefore be used in new buildings and old buildings undergoing renovation. With the latest generation of heat pumps, flow temperatures of up to 70° can be achieved.
However, it may be worth replacing or adding new radiators with a larger heating surface area in order to increase the efficiency of the heat pump. Seek advice from a specialist. In general, energy-saving measures should be considered for the building envelope in order to directly reduce the heat demand and thus reduce the flow temperatures and increase the efficiency of the heat pump.

Yes, because all our heat pump systems are designed for the design temperature. However, there are some differences between the various heat pump systems that need to be taken into account:

Air/water heat pumps:
Air/water heat pumps have a lower operating limit (approx. -25°C). For heating systems, this means that the heat output is guaranteed up to the design temperature (in the Swiss Plateau, for example, at -7°C). If the outside temperature falls below this design temperature, the auxiliary heating can switch on automatically. Statistically speaking, however, this is extremely rare.

Brine/water heat pumps:
With brine/water heat pumps, it is important to dimension the geothermal probes correctly. The geothermal energy at depth is constant and changes only minimally, even if the top layer of soil is frozen.

A heat pump with a COP of 5 requires 1/5 of the total energy produced in the form of electrical energy, while 4/5 of the energy is obtained from the environment (ambient air, geothermal probe, etc.).
The COP is highly dependent on the source temperature and the flow temperature. The higher the source temperature and the lower the flow temperature, the higher the COP and the energy efficiency.
In combination with a PV system, the amount of electricity consumed can be increased and energy costs reduced.

The sound insulation of heat pumps can be improved through structural measures. The most important measure is to physically decouple the heat pump from the house. Pipes must also be physically decoupled using suitable mounting systems. Sound insulation hoods or sound insulation walls can also significantly reduce noise levels.

Heat pumps are generally very low-maintenance. However, a heat pump should not be neglected. Contamination on the outdoor unit or in the heating circuit, incorrect settings, incorrect heating curves, etc. can damage the heat pump or reduce its efficiency. Periodic maintenance is therefore always beneficial and extends the service life.

Luft/Wasser-Wärmepumpe NIBE F2120

NIBE F2120 is the air/water heat pump for maximum efficiency in new build, modernization or for replacing your existing heating system. It achieves a peak value with a maximum flow temperature of 63°C at -25°C outside temperature. Active cooling is possible down to +7°C flow temperature. While you enjoy maximum comfort, you also make a contribution to environmental protection.

Whis­per quiet ope­ra­ti­on

Thanks to optimized technology

Mi­ni­mum ope­ra­ting costs

Through inverter technology to the optimal

Power ran­ge

Possibility of combining up to 8 heat pumps in cascade

Mi­le­stone in ef­fi­ci­en­cy

With a SCOP greater than 5.0

Workspace for any cli­ma­te

Flow temperature up to 65°C

No vi­gnet­te ob­li­ga­ti­on

Refrigerant not over 3 kg

Over­view and sta­tus

Through the Internet connection of myuplink the full control and monitoring even remotely