Air-to-water heat pump NIBE F2120

The NIBE F2120 is the air/water heat pump for maximum efficiency in new build, modernisation or for replacing your existing heating system.

area of application
Single-family house, multi-family house, new construction, renovation
Heat source
Air
Lineup
Outdoor installation
Power range
2.2 - 15.4 kW / Cascadable up to 8 units (max. 108 kW for A-7/W35)
NIBE Air-to-Water Heat Pump-F2120

Product details

The advantages of the NIBE F2120 at a glance:

  • Whisper-quiet operation
    Thanks to a sound power level of 53-55 dB(A) according to ERP (EN12102)
  • Minimum operating costs
    Through inverter technology to the optimum power range
  • Combination possibility
    up to 8 heat pumps in cascade
  • Milestone in efficiency
    With a SCOP greater than 5.0
  • Working range for any climate
    Flow temperature up to 65 °C
  • No vignette obligation
    Refrigerant not over 3 kg
  • Overview and status
    Through the Internet connection myuplink the full control and monitoring even remotely

Climate premium

Are you replacing a fossil gas or oil heating system with a renewable heating system? Benefit from attractive subsidies.

References

  • Schmid heat pump air-to-water F2120-NIBE

    Single family house | F2120 | Ambient air

    Faber, 8360 Eschlikon

Do you have any questions?

Benefit from our many years of experience and let our specialists advise you individually, without obligation and free of charge.

Frequently asked questions?

An air-to-water heat pump extracts energy from the ambient air, transfers it to the refrigerant, and uses a compressor to produce heat that is used for heating and domestic hot water. In summer, the process can be modified for cooling.

A brine-to-water heat pump uses geothermal energy. To do this, it draws thermal energy from the ground and conducts the heat into the house. The heat extraction works even if the upper layer of the earth is frozen in winter, because the geothermal heat remains constant.

The heat pumps are suitable for both and and can thus be used in new buildings and renovation properties. The maximum flow temperature in continuous operation should not exceed 55°C, as the efficiency decreases sharply.

However, it is worth replacing the old radiators with new ones with a larger heating surface. Seek advice from specialists. In general, energy-saving measures on the building envelope to directly reduce the heat demand and thus the flow temperatures should be examined.

Yes, because all our heat pump systems are designed for the design temperature. However, there are some differences between the various heat pump systems that need to be considered:

Air-to-water heat pumps:

Air-to-water heat pumps have a lower operating limit of approx. -25°C. For heating systems, this means that the heat output is guaranteed up to the design temperature (in the midlands, for example, at -7°C outside temperature). If the outside temperature drops below this design temperature for one or more days, the auxiliary heating switches on automatically. Statistically, however, this case occurs only very rarely.

Brine-to-water heat pumps:

With these heat pumps, the correct dimensioning of the geothermal probes is important. The heat at depth is constant and changes only minimally, even if the upper layer of the earth is frozen.

The heat pump needs on average 7'200 kWh per year, but this is strongly dependent on the energy requirement of the building. A heat pump in combination with a photovoltaic system makes sense and helps to reduce the cost of electricity consumption.

The sound insulation of heat pumps can be improved by structural measures. The most important is the physical decoupling of floors, walls and pipes. Sound insulation hoods or sound insulation walls can also significantly reduce noise generation.

Heat pumps are in principle very low maintenance. However, a heat pump should not be neglected. Dirt on the outdoor unit or in the heating circuit, incorrect settings, wrong heating curve, etc., can damage the heat pump or its efficiency. Therefore, a periodic maintenance is always advantageous and extends the life expectancy.

Air-to-water heat pump NIBE F2120

NIBE F2120 is the air/water heat pump for maximum efficiency in new build, modernization or for replacing your existing heating system. It achieves a peak value with a maximum flow temperature of 63°C at -25°C outside temperature. Active cooling is possible down to +7°C flow temperature. While you enjoy maximum comfort, you also make a contribution to environmental protection.

Whisper quiet operation

Thanks to a sound power level of 53-55 dB(A) according to ERP (EN12102)

Minimum operating costs

Through inverter technology to the optimal

Power range

Possibility of combining up to 8 heat pumps in cascade

Milestone in efficiency

With a SCOP greater than 5.0

Workspace for any climate

Flow temperature up to 65°C

No vignette obligation

Refrigerant not over 3 kg

Overview and status

Through the Internet connection of myuplink the full control and monitoring even remotely